Description
- Range 1 0-60 seconds adjusted by the potentiometer
- Range 2 1-60 minutes selected by plug in link JP2
- Two modes of operation are provided and are selected by plug in link JP1.
- Mode 1 Link pins 1 and 2 on JP1. The relay activates for the timed period. In Mode 1 there are 2 options.
- A. With JP4 link out the relay activates for a timed period and then de-energises even if a trigger is still present. The timer will reset after removal of the trigger input.
- B. With JP4 link in the relay will activate for the timed period and then de-energise. The timer will lock out until reset pins JP3 is shorted.
- Mode 2 Link pins 2 and 3 on JP1. The relay activates after the timed period. In Mode 2 there are 2 options.
- A. Relay activates momentarily after the timed period (link JP4 out). If a trigger is still present after the timed period the relay will stay energised until the trigger is removed.
- B. Relay latched on (link JP4 in) until reset pins JP3 shorted momentarily.
- Mode 1 Link pins 1 and 2 on JP1. The relay activates for the timed period. In Mode 1 there are 2 options.
- Trigger inputs: The timer will start when an input is applied to the T terminal. This may be positive or negative voltage. The input can be a brief pulse or a continuous signal.